This part of ISO 16486 specifies the requirements of fitness for purpose of the unplasticized polyamide (PA-U) piping system, intended to be buried and used for the supply of gaseous fuels. It also specifies the definitions of electrofusion and butt fusion joints.
This part of ISO 16486 specifies the method of preparation of test piece joints and the tests to be carried out on these joints for assessing the fitness for purpose of the system under normal and extreme conditions. It also specifies the test parameters for the test methods to which it refers.
ISO 16486 is applicable to PA-U piping systems the components of which are connected by fusion jointing and/or mechanical jointing.
In conjunction with the other parts of ISO 16486, it is applicable to PA-U fittings, their joints and to joints with components of PA-U.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for the determination of the carbon black content of polyolefin compositions used in particular for the manufacture of pipes and fittings, and provides a basic specification for polyethylene pipes and fittings.
This document applies equally to the material for manufacture and to any material taken from a pipe or fitting.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    9 pages
    English language
    sale 15% off

This document gives the recommended practise for underground open trench installation and commissioning of thermoplastics piping systems to be used for the conveyance of water under pressure (in addition to EN 805) and for the discharge of wastewater under gravity (in addition to EN 1610) .
In the field of non-pressure underground drainage and sewerage this is reflected in the marking of products by application code "U" and "UD":
-   outside the building structure (U);
-   both buried in ground within the building structure (application area code "D") and outside the
building (application area code "UD").
This document covers also installation and/or connections to valves, manholes, inspection chambers, gullies and other ancillary components in piping systems.
NOTE 1   Code of practise for pipelines for gas supply is covered by EN 12007-series [21].
NOTE 2   Recommended practices for installation of plastic piping systems for soil and waste discharge within the building structure is covered by CEN/TR 13801 [12].
NOTE 3   Practices for underground installation of rainwater infiltration and storage attenuation systems are covered by CEN/TR 17179 [13].
NOTE 4   It is assumed that additional recommendations and/or requirements are detailed in the individual product standards.
NOTE 5    If non-plastic components are part of the plastic system the manufacturer's instructions should be taken into account.
Requirements and instructions concerning commissioning of systems can be found in EN 805 and EN 1610 and the relevant national and/or local regulations. This document gives specific additional recommendations for commissioning relevant for plastic piping systems.
Attention is drawn to any relevant local and/or national regulations (e.g. health, safety and hygienic requirements).

  • Technical specification
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard, in conjunction with ISO 11298-1, specifies requirements and test methods for cured-in-place pipes and fittings used for the renovation of underground water supply networks. It applies to the use of various thermosetting resin systems, in combination with compatible fibrous carrier materials and other process-related plastics components.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1329 1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third party certification is involved, the certification body is expected to be compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [3], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1329 1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC U) intended for soil and waste discharge systems (low and high temperature):
-   inside buildings (application area code "B");
-   both inside buildings and buried in ground within the building structure (application area code "BD").

  • Technical specification
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems intended for soil and waste discharge applications (low and high temperature):
-   inside buildings (application area code "B");
-   for both inside buildings and buried in ground within the building structure (application area code "BD").
NOTE 1   The intended use is reflected in the marking of products by "B" or "BD".
NOTE 2   Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 1453-1 [1].
NOTE 3   For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm.
NOTE 4   EN 476 [2] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this standard fully meet these requirements.
This document is also applicable to PVC-U pipes, fittings and the system intended for the following purposes:
-   ventilating part of the pipework in association with discharge applications;
-   rainwater pipework within the building structure.
This document also specifies the test parameters for the test method that are referred to.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
NOTE 5   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user.
NOTE 6   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 25.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides a scheme for the assessment of conformity of PE products and assemblies for the rehabilitation of existing pipelines, in accordance with the applicable parts of ISO 11296, ISO 11297, ISO 11298, ISO 11299 and ISO 21225, and intended to be included in the manufacturer's quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE In order to help the reader, summary tables of overall scheme requirements are provided in Annex E.

  • Technical specification
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 16486 specifies the physical and mechanical properties of pipes made from unplasticized polyamide (PA-U) in accordance with ISO 16486-1, intended to be buried and used for the supply of gaseous fuels. It also specifies the test parameters for the test methods to which it refers.
ISO 16486 is applicable to PA-U piping systems the components of which are connected by fusion jointing and/or mechanical jointing.
In addition, it lays down dimensional characteristics and requirements for the marking of pipes.
Pipes conforming to this part of ISO 16486 are jointed typically by using mechanical, electrofusion or butt fusion (see Annex A) techniques, but not by solvent cement jointing.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 16486 specifies the physical and mechanical properties of fittings made from unplasticized polyamide (PA-U) in accordance with ISO 16486-1, intended to be buried and used for the supply of gaseous fuels.
It also specifies the test parameters for the test methods to which it refers.
ISO 16486 is applicable to PA-U piping systems the components of which are connected by fusion jointing and/or mechanical jointing.
In addition, it lays down dimensional characteristics and requirements for the marking of fittings.
In conjunction with the other parts of ISO 16486, it is applicable to PA-U fittings, their joints, to joints with components of PA-U and to joints with mechanical fittings of other materials, and to the following fitting types:
    — fusion fittings — electrofusion fittings and butt fusion fittings;
    — transition fittings.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 6259 specifies a method of determining the tensile properties of pipes made of unplasticized poly(vinyl chloride) (PVC-U), oriented unplasticized poly(vinyl chloride) (PVC-O), chlorinated poly(vinyl chloride) (PVC-C) and high-impact poly(vinyl chloride) (PVC-HI), and in particular the following properties:
— the stress at yield;
— the stress and the elongation at break.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 16486 specifies the general properties of unplasticized polyamide (PA-U) compounds for the manufacture of pipes, fittings and valves made from these compounds, intended to be buried and used for the supply of gaseous fuels. It also specifies the test parameters for the test methods to which it refers.
ISO 16486 is applicable to PA-U piping systems the components of which are connected by fusion jointing and/or mechanical jointing

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for determining the leaktightness of elastomeric sealing ring
type joints for buried thermoplastics non-pressure piping systems.
Unless otherwise specified in the referring standard, the tests are carried out at the following basic test
pressures:
— p1: internal negative air pressure (partial vacuum);
— p2: a low internal hydrostatic pressure;
— p3: a higher internal hydrostatic pressure.
It also describes the following four test conditions under which the tests are performed:
a) Condition A: without any additional diametric or angular deflection;
b) Condition B: with diametric deflection;
c) Condition C: with angular deflection;
d) Condition D: with simultaneous angular and diametric deflection.
The applicable selection of the test pressure(s) and the test condition(s) is/are specified in the referring
standard.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of compounds/formulations, products, joints and assemblies in accordance with the applicable parts of EN 17176 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If certification is involved, it is recommended that the certification body is accredited to EN ISO/IEC 17065 [2] or ENISO/IEC 17021 [3], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 17176-1, EN 17176-2, CEN/TS 17176-3 and EN 17176-5, this document is applicable to oriented unplasticized poly(vinyl chloride) (PVC-O) plastics piping systems for water supply and for buried and above-ground drainage, sewerage and irrigation under pressure.

  • Technical specification
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with EN 1519 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If certification is involved, it is recommended that the certification body is compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [4], as applicable.
NOTE 3   A basic test matrix providing an overview of the testing scheme is given in Annex A.
In conjunction with EN 1519-1 this document is applicable to piping systems made of polyethylene (PE) intended to be used:
-   for soil and waste discharge systems (low and high temperature) inside buildings (application area code "B") and
-   for soil and waste discharge systems (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD").
This is reflected in the marking of products by "B" or "BD".

  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and external surfaces, designated as Type A.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a)   structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure; reflected in the marking of products by "U";
b)   structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code "U") and within the building structure (application area code "D"); reflected in the marking of products by "UD".
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and profiled external surfaces, designated as Type B.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a)   structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure, reflected in the marking of products by "U";
b)   structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code "U") and within the building structure (application area code "D"), reflected in the marking of products by "UD".
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the definitions and requirements for unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) manholes and inspection chambers intended for non-pressure underground drainage and sewerage systems to a maximum depth of 6 m from ground level to the invert of the manhole or inspection chamber.
This document covers manholes and inspection chambers with flow profile bases, and their joints to the piping system.
Manholes and inspection chambers are intended to be used in pedestrian or vehicular traffic areas outside the building structure.
NOTE 1   The intended use in underground installation outside the building structure is reflected in the marking of products by the application area code "U".
NOTE 2   Products complying with this document may also be used in non-traffic areas.
NOTE 3   Products complying with this standard can be installed in underground applications without additional static calculation.
NOTE 4   Shallow chambers are specified in EN 13598-1.
Manholes and inspection chambers complying with EN 13598-2 are made from a prescribed set of components that are manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) and assembled together.
NOTE 5   The complete manhole or inspection chamber assembly may also include non-plastic items (near surface or surface components for example) which are not covered by this document.
NOTE 6   Manholes and inspection chambers may be supplied with covers, frame covers and gratings complying with the relevant part of EN 124 [1].
Manholes and inspection chambers complying with EN 13598-2 comply with the general requirements given in EN 476.
Manholes and inspection chambers complying with EN 13598-2 may be used for storm-water systems.
Manhole and inspection chamber components can be manufactured by various methods e.g. extrusion, injection moulding, rotational moulding, low-pressure moulding or fabricated.
NOTE 7   Manholes and inspection chambers can be site assembled from different components, but can also be manufactured as a single unit.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the definitions and requirements for ancillary fittings and shallow chambers installed underground in non-pressure drainage and sewerage systems and manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) intended for use for:
-   non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
-   non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
It also covers the jointing of the ancillary fittings and shallow chambers to the pipework system.
The ancillary fittings covered by this standard are the following:
-   sealed access fittings;
-   rodding point covers;
-   rodding tees;
-   mechanical saddles.
Ancillary fittings according to this document are intended for use in pedestrian or vehicular traffic areas.
Ancillary fittings can be installed to a maximum depth of 6,0 m from ground level, with the exception of rodding point covers.
Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main channel. This document covers shallow chambers with flow profile bases, and their joints to the piping system.
NOTE 1   EN 124-series [1] and EN 1253-4 [2] covers may be used for shallow chambers.
NOTE 2   Manholes and inspection chambers are specified in EN 13598-2.
Ancillary fittings and shallow chambers complying with EN13598-1 comply with the general requirements given in EN 476.
Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated from components made to other standards.
NOTE 3   Product complying with this document may be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Clause 2, provided their dimension comply with the requirements for joint dimensions given in Clause 7 and to the requirements of Table 6.
NOTE 4   Products complying with this document can be installed in underground applications without additional static calculation.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1401-1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1 The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2 If third party certification is involved, the certification body is expected be compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [3], as applicable.
NOTE 3 In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1401-1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended for non-pressure underground drainage and sewerage:
— buried in ground outside the building structure (application area code “U”);
— both buried in ground within the building structure and outside the building structure (application area code “UD”).

  • Technical specification
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 13476 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   The quality management system is expected to conform to or be no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, the certification body can be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3 In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 13476 1, EN 13476 2 and EN 13476 3 this document is applicable to Plastics piping systems for non-pressure underground drainage and sewerage — Structural-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE):
-   for non-pressure underground drainage and sewerage outside the building structure (application area code “U”) reflected in the marking of products by “U”, and
-   for non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D” and outside the building structure (application area code “U”) reflected in the marking of products by “UD”.

  • Technical specification
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 1852 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   The quality management system is expected to conform to or be no less stringent than the relevant requirements in EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, the certification body is expected be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1852-1 this document is applicable to solid wall piping systems made of polypropylene (PP) intended to be used for:
-    non-pressure underground drainage and sewerage outside the building structure (application area code “U”), and
-   non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D”) and outside the building structure.
This is reflected in the marking of products by “U” and “UD”.

  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 1451 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, the certification body is expected be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3   In order to help the readers, a summary of the test regime is given in Annex A.
In conjunction with EN 1451 1 this document is applicable to piping systems made of polypropylene (PP) intended to be used:
-   for soil and waste discharge systems (low and high temperature) inside buildings (application area code “B”) and,
-   for soil and waste discharge systems (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code “BD”)
This is reflected in the marking of products by “B” or “BD”.

  • Technical specification
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical specification
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining short term compression strength on boxes made of thermoplastics materials for non-pressure underground conveyance and storage of non-potable water.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for determining the long-term compression strength for a specified period on structural boxes made of thermoplastics materials for non-pressure underground conveyance and storage of non-potable water.
The document is applicable for boxes which maintain their linear behaviour over the specified period.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives the definitions and specifies the minimum requirements for injection moulded, extruded and thermoformed thermoplastics cuboid shaped boxes, including integral components, used in underground systems for infiltration, attenuation and storage of non-potable water (e.g. storm water) and manufactured from unplasticized poly(vinyl chloride) (PVC-U) or polypropylene (PP).
NOTE 1   Specifications and design rules for systems (water reservoir) are described in part 2 of EN 17152.
Product properties are determined by a combination of material specifications, design and manufacturing process.
These boxes are intended for buried underground use, e.g. in landscape, pedestrian or vehicular traffic areas.
A box can either be factory assembled or site assembled from different components.
These boxes are intended to be used as elements in a modular system where the manufacturer has clearly stated in the documentation how the components are assembled to create a complete infiltration, attenuation or storage construction.
NOTE 2   Non load bearing component(s) can be manufactured by various methods e.g. extrusion, injection moulding, rotational moulding, thermoforming and low-pressure injection moulding.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of compounds,
products, and assemblies in accordance with the applicable part(s) of ISO 21003 intended to be included
in the manufacturer’s quality plan as part of the quality management system and for the establishment
of certification procedures.
In conjunction with the other parts of ISO 21003 (see Foreword), this document is applicable to
multilayer piping systems intended to be used for hot and cold water installations within buildings for
the conveyance of water, whether or not intended for human consumption (domestic systems) and for
heating systems, under design pressures and temperatures appropriate to the class of application (see
ISO 21003-1:2008, Table 1).

  • Technical specification
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC U) piping systems in the field of non-pressure underground drainage and sewerage:
-   buried in ground outside the building structure (application area code "U"), and
-   both buried in ground, within the building structure (application area code "D") and outside the building.
This is reflected in the marking of products by "U" and "UD".
It also specifies the test parameters for the test methods referred to in this document.
NOTE 1   Solid wall multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 13476-2 [1] (see also CEN ISO/TR 27165 [2]).
This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with prCEN/TS 1401-2 [3], it is applicable to PVC U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
NOTE 3   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 15.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of prEN 17176 specifies the characteristics of solid-wall elbows, double sockets, repair couplings and reducers fittings made from oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure and irrigation under pressure.
NOTE 1   The scope of this part is restricted to fittings on the market during the preparation of this standard. Therefore tees, flange adaptors, etc., are excluded from this version of the standard.
It also specifies the test parameters for the test methods referred to this part of prEN 17176.
In conjunction with prEN 17176-1, prEN 17176-2 and prEN 17176-5, it is applicable to oriented PVC-O fittings and to joints with components of PVC-O, PVC-U (EN ISO 1452 3), other plastics and non-plastics materials such as cast iron fittings (EN 12842) intended to be used for the following:
a)   water mains and services lines in the ground;
b)   conveyance of water for both outside and inside buildings;
c)   drainage, sewerage and treated waste water under pressure;
d)   irrigation under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water and water for irrigation under pressure.
This part of prEN 17176 specifies fittings for the conveyance of water intended for human consumption, waste water and water for irrigation up to and including 45 °C. For temperatures between 25 °C and 45 °C, prEN 17176-2:2017, Figure C.1 applies.
The piping system according to this European Standard is intended for the conveyance of cold water up to pressures of 25 bars and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar.
This part of prEN 17176 specifies a range of fittings sizes and pressure classes and gives a requirement and recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

  • Technical specification
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of prEN 17176 specifies the general aspects of oriented unplasticized poly(vinyl chloride) (PVC-O), for solid wall piping systems intended for water supply, pressurized sewer systems and irrigation systems to be used underground or above-ground where protected to direct sunlight.
In conjunction with prEN 17176-2, prEN 17176-3, EN ISO 1452 4, it is applicable to PVC-O pipes, PVC-O fittings, and valves, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following:
a)   water mains and services lines;
b)   conveyance of water for both outside and inside buildings;
c)   drainage, sewerage and treated waste water under pressure;
d)    Irrigation under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for waste water under pressure.
This part of prEN 17176 is also applicable to components for the conveyance of water and waste water up to and including 45 °C. For temperatures between 25 °C and 45 °C, prEN 17176-2:2017, Figure C.1 applies.
The piping system according to this European Standard is intended for the conveyance of cold water up to pressures of 25 bars and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bars.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of prEN 17176 specifies the characteristics for the fitness for purpose of oriented unplasticized poly(vinyl chloride) (PVC-O) piping systems intended for water supply, pressurized sewer systems and irrigation systems to be used underground or above-ground where protected to direct sunlight.
In conjunction with prEN 17176-2, prEN 17176-3, EN ISO 1452 3, EN ISO 1452 4 and EN 12842 this part is applicable to PVC-O pipes, PVC-O and PVC-U fittings, cast iron fittings and valves, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following:
a)   water mains and services lines;
b)   conveyance of water for both outside and inside buildings;
c)   drainage and sewerage under pressure;
d)   irrigation under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water and water for irrigation under pressure.
This part of prEN 17176 is also applicable for the conveyance of water, waste water and water for irrigation up to and including 45 °C. For temperatures between 25 °C and 45 °C, prEN 17176-2:2017, Figure C.1 applies.
NOTE    It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of prEN 17176 specifies the characteristics of solid-wall pipes made from oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended for water supply and for buried and above-ground drainage, sewerage, treated waste water and irrigation under pressure.
It also specifies the test parameters for the test methods referred to this part of prEN 17176.
In conjunction with prEN 17176-1 and prEN 17176-5, it is applicable to oriented PVC-O pipes with or without integral socket intended to be used for the following:
a)   water mains and services lines;
b)   conveyance of water for both outside and inside buildings;
c)   drainage, sewerage and treated waste water under pressure.
d)   irrigation under pressure
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water and water for irrigation under pressure.
This part of prEN 17176 specifies pipes for the conveyance of water, waste water and water for irrigation up to and including 45 °C. For temperatures between 25 °C and 45 °C, EN ISO 1452-2:2009, Figure C.1 applies.
This part of prEN 17176 specifies a range of pipe sizes and pressure classes and gives requirements concerning colours.
The piping system according to this European Standard is intended for the conveyance of cold water up to pressures of 25 bars ) and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bars.
NOTE   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for pipes, fittings and the system of polyethylene (PE) solid-wall piping systems in the field of soil and waste discharge - inside buildings (marked with "B") and - for both inside buildings and buried in ground within the building structure (marked with "BD"). It also specifies the test parameters for the test methods referred to in this standard.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document, in conjunction with ISO 11296-1, specifies requirements and test methods for pipes
which are formed on site by spirally winding and jointing a pre-manufactured profiled plastics strip,
or a profiled plastics strip and integral locking joiner strip, and used for the renovation of underground
non-pressure drainage and sewerage networks.
It applies to spirally-wound pipes of fixed or variable diameter made of profiled plastics strips, with or
without steel stiffening elements, and installed by one of two methods.
The first method employs a dedicated winding machine in front of the open end of an existing pipeline,
e.g. in a manhole. The pipes thus formed are simultaneously inserted into the existing pipeline by the
winding forces, and by certain techniques can also be expanded in diameter after or during insertion.
The second method employs a dedicated winding machine which forms the pipe as it traverses the
existing pipeline from one manhole to the next.
It applies to profiled plastics strips of unplasticized poly(vinyl chloride) (PVC U) with integral locking
mechanism, or of high density polyethylene (HDPE) with integrally welded joints.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for determining the resistance to elevated temperature cycling
of thermoplastics piping systems for non‑pressure applications, inside buildings or buried in the ground
within the building structure.
This document is applicable to piping systems with components of nominal outside diameters up to and
including 200 mm.
Although limited to nominal outside diameters up to and including 200 mm, the test results may be
extrapolated to products of larger nominal outside diameters from the same range.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 15877 gives guidance for the assessment of conformity of materials, products, and assemblies in accordance with the applicable part(s) of ISO 15877 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of  certification procedures.
In conjunction with the other parts of ISO 15877 (see Foreword), this Technical Specification (International Standard) is applicable to Chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see Table 1 of ISO 15877-1:2009).

  • Technical specification
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day