IEC 61467:2008 applies to insulator strings and sets comprising string insulator units of ceramic material, glass or composite material for use on a.c. overhead lines and traction lines with a nominal voltage above 1 000 V and a frequency between 15 Hz and 100 Hz. This standard also applies to insulator strings or sets of similar design used in substations. This standard establishes a standard test procedure for power arc tests on insulator sets. It also establishes a standard test procedure for power arc tests on short strings. This standard does not apply to insulator sets mounted on non-metallic poles or towers. This edition cancels and replaces IEC/TR 61467, which was published as a technical report in 1997. It constitutes a technical revision and now has the status of an International Standard.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    44 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    45 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 61109:2008 applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. The main technical changes with respect to the previous edition are - removal of tests procedures now given in IEC 62217; - inclusion of clauses on tolerances, environmental conditions, transport, storage and installation; - general improvement of the description of tests and addition of a new Annex C on non-standard loads.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    32 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    33 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 61952:2008 applies to composite line post insulators consisting of a load-bearing, cylindrical, insulating solid core made up of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings permanently attached to the insulating core. The object of this standard is to - define the terms used, - prescribe test methods, - prescribe acceptance or failure criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions. This edition includes the following significant technical changes with respect to the previous edition: - removal of tests procedures now given in IEC 62217; - inclusion of clauses on tolerances, environmental conditions, transport, storage and installation; - changes in the parameters determining the need to repeat design and type tests; and - modification of the specification of load application in bending tests to simplify testing.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Deals with impulse puncture testing in air of ceramic and glass insulator units of class B: cap and pin, pin type (including pin-post type) and class B long rod insulators. May be applied also in tests on Class B insulators of other materials (e.g. polymers and composites). However, it may be useful to consider the possible need to adjust the test procedure accordingly.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applicable to locking devices used with ball and socket couplings of string insulator units and used with the corresponding metal fittings standardized in EN 60120. -Defines the shapes and some standard dimensions for locking devices as well as the test methods for locking devices; -States the acceptance conditions for supply and gives other dimensions for guidance of manufacturing only. Replaces EN 60372-1 (1977) and 60372-2 (1976).

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Is applicable to composite string insulators with a specified mechanical load (SML) of 40 kN and 70 kN for a.c. overhead distribution lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to insulators of similar design used in substations or on electric traction lines.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Prescribes specified values for the electrical and mechanical characteristics and for the principal dimensions of string insulator units of the long rod type with insulating parts of ceramic material intended for a.c. overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It is also applicable to insulators of similar design, used in substations. Applies also to string insulator units: -of the long rod type either with a clevis at both ends for coupling with a tongue, or with a socket at both ends for coupling with a pin ball -with external metal fittings -for use on overhead lines situated in slightly polluted areas, and the creepage distances given in Tables I and II have been established accordingly -and insulators of similar design, used in substations. This standard may be regarded as a provisional standard for insulators for d.c. overhead lines. Note -For general definitions and methods of tests see EN 60383. -For dimensions of clevis and tongue couplings of string insulator units, see IEC 60471. -For dimensions of ball and socket couplings of string insulator units, see EN 60120.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to insulators of ceramic material or glass for use on a.c. overhead power lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. Also applies to insulators for use on d.c. overhead electric traction lines and applies to string insulator units, rigid overhead line insulators and to insulators of similar design when used in substations.

  • Standard
    62 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to string insulator units of the cap and pin type with insulating parts of ceramic material or glass, intended for a.c. overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz and to insulators of similar design used in substations.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Is applicable to string insulator units of ceramic material or glass for use on d.c. overhead power lines with a nominal voltage greater than 1 000 V. This standard specifies: -the characteristics of insulators; -the conditions under which the specified values of these characteristics shall be verified; -acceptance criteria

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to insulator strings and insulator sets comprising string insulator units of ceramic material or glass for use on a.c. overhead power lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. This part of EN 60383 also applies to insulator strings and insulator sets for use on d.c. overhead electric traction lines. This part of EN 60383 also applies to insulator strings and insulator sets of similar design when used in substations.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to string insulator units of the cap and pin and long rod types and their associated metal fittings for overhead lines. Includes six standard sizes designated by the nominal pin diameters which form the basis of the standard. Defines each standard size by the dimensions of the pin ball, of the socket and the hook-on 'Go' gauge. States dimensions of twin-balled pins for coupling of two sockets. Tabulates clearance and locking conditions. Appendices give information on extreme positions of the pin ball in the socket as well as on gauges for checking dimensions.

  • Standardization document
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to composite line post insulators consisting of a load-bearing, cylindrical, insulating solid core made up of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings permanently attached to the insulating core. The object of this standard is to - define the terms used, - prescribe test methods, - prescribe acceptance or failure criteria This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Prescribes specified values for the mechanical characteristics of the composite string insulator units. Defines the main dimensions of the couplings to be used on the composite string insulator units in order to permit the assembly of insulators of fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also defines a standard designation system for composite string insulator units.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day