EN 50131-13:2020/AC:2021-04
(Corrigendum)Alarm systems - Intrusion and hold-up systems - Part 13: Pyrotechnic Obscuration Security Devices
Alarm systems - Intrusion and hold-up systems - Part 13: Pyrotechnic Obscuration Security Devices
2021-05-03: TC to correct wording in 13.3.2
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 13: Pyrotechnisches Verrauchungs-Gerät
Systèmes d’alarme - Systèmes d’alarme contre l’intrusion et les hold-up - Partie 13: Dispositifs de sécurité pyrotechniques à pouvoir opacifiant
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 13. del: Varnostne pirotehnične zamegljevalne naprave - Popravek AC
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50131-13:2020/AC:2021
01-junij-2021
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 13. del: Varnostne
pirotehnične zamegljevalne naprave - Popravek AC
Alarm systems - Intrusion and hold-up systems - Part 13: Pyrotechnic Obscuration
Security Devices
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 13: Pyrotechnisches
Verrauchungs-Gerät
Systèmes d’alarme - Systèmes d’alarme contre l’intrusion et les hold-up - Partie 13:
Dispositifs de sécurité pyrotechniques à pouvoir opacifiant
Ta slovenski standard je istoveten z: EN 50131-13:2020/AC:2021-04
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm
...
This May Also Interest You
This document specifies the minimum requirements for monitoring, receiving and processing of alarm messages generated by alarm systems taking place as a part of the total fire, safety and security solution. For the purpose of this document, the term “alarm” is used in the broad sense to include fault, status and other messages received from one or more of a range of safety and security alarm systems such as but not limited to fire detection and fire alarm systems, fixed firefighting systems, intrusion and hold-up alarm systems, access control systems, video surveillance systems, social alarms systems and combinations of such systems. This document gives requirements for two categories of ARC, category I and category II. A category I ARC will be designed, constructed and operated to a higher standard with respect to construction, security and integrity than a category II ARC. The categorization is determined according to the type(s) of alarm messages handled. Category I: ARCs handling messages from security applications: - I&HAS’s; - access control systems; - VSS in security applications that require an emergency response (for example loss prevention); - people monitoring, lone workers and object tracking systems for security applications; - alarm messages handled by category II ARCs; - combinations of the above systems. Category II: ARC’s handling messages from non-security applications: - fire alarm systems; - fixed firefighting systems; - social alarm systems; - audio/video door entry systems; - VSS in non-security applications (for example traffic flow); - people monitoring, lone workers and object tracking systems for non-security applications; - lifts emergency systems; - combinations of the above systems. The requirements apply to ARC’s (whether established in single or multiple sites) monitoring and processing alarms generated by systems installed at other locations and also to ARC’s monitoring solely alarms from systems within their own site. The document includes functional and specific requirements supporting the services of an ARC. The document does NOT apply to: - alarm systems used for non-civil purposes; - alarm systems for medical or health applications.
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the general equipment requirements for the performance, reliability, resilience, security and safety characteristics of supervised premises transceiver (SPT) installed in supervised premises and used in alarm transmission systems (ATS). A supervised premises transceiver can be a stand-alone device or an integrated part of an alarm system. These requirements also apply to SPT’s sharing means of interconnection, control, communication and power supplies with other applications. The alarm transmission system requirements and classifications are defined within EN 50136-1. Different types of alarm systems may in addition to alarm messages also send other types of messages, e.g. fault messages and status messages. The term alarm is used in this broad sense throughout the document. Additional requirements for the connection of specific types of alarm systems are given in the relevant European Standards. Because the SPT can be applied in different applications (e.g. I&HAS, fire and social alarm systems), requirements for the SPT, additional to those of this European Standard, may be specified in separate application specific documents. This European Standard specifies the requirements specific to alarm transmission. Application specific requirements for the connection of the SPT to specific types of alarm systems are given in the EN/TS 50131 series for I&HAS, and EN 54 series for fire. For other SPT applications, see the relevant National or European standards.
- Amendment13 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of the IEC 62676 series specifies management systems interfaces and mechanism for remote operational access to physical security devices such as video surveillance devices and systems. For video surveillance, the use cases focus on accessing live video and retrieving recordings. The mechanism defined in this specification are not restricted to surveillance applications but also cover remote access to security systems and electronic access control systems. Configuration of devices and management systems is out of scope of this specification. Clause 4 introduces to remote management access. Clause 5 defines a set of requirements that the protocol needs to fulfil. Clause 6 extends the token-based resource-addressing scheme of the underlying specification IEC 60839-11-31. Clause 7 describes how to retrieve information about remote resources. Clause 8 defines how to connect to devices that are not directly reachable because they are e.g. located behind firewalls.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies minimum requirements for secure connection and session for remote access to one or more alarm systems, for example fire safety systems, intruder and hold-up alarm systems, electronic access control systems, external perimeter security systems, video surveillance systems, and social alarm systems. This document specifies the requirements for the performance, reliability, integrity, and security characteristics of a Remote Access Infrastructure. This document specifies the requirements for a Remote Access Infrastructure between a Remote Access Client and an alarm system at the supervised premises and may be either integrated as part of the ATS or a separate infrastructure. In either case, the requirements of this European technical specification should apply. This document does not cover the provision of functions and features on the alarm system.
- Technical specification12 pagesEnglish languagesale 10% offe-Library read for×1 day
IT NC submits to CLC TC79 the request for an amendment work of the EN 62820-1-1:2016, within CLC/TC 79/WG 15
- Amendment7 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131 1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130 5). This document does not include requirements for detectors intended for use outdoors. The purpose of the detector is to emit microwave signals and analyse the signals that are returned to detect an intruder and to provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system. The grade-dependent requirements of this document apply and it is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the detector, providing they do not influence the correct operation of the mandatory functions. Requirements for system interconnections are not included in this document.
- Standard46 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 60839 defines the Web services interface for electronic access control systems. This includes listing electronic access control system components, their logical composition, monitoring their states and controlling them. It also includes a mapping of mandatory and optional requirements in accordance with IEC 60839-11-1:2013, as covered by Annex B. This document applies to physical security only. Physical security prevents unauthorized personnel, attackers or accidental intruders from physically accessing a building, room, etc. Web services usage and device management functionality are outside the scope of this document. Refer to IEC 60839-11-31:2016 for more information. This document does not in any way limit a manufacturer to add other protocols or extend the protocol defined here. For rules on how to accomplish this, refer to IEC 60839-11-31:2016.
- Standard185 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the minimum requirements for the performance, reliability and security characteristics of interconnections, alarm transmission systems and communications within a social alarm system.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the minimum equipment requirements for the performance, reliability, resilience, security and safety characteristics of the receiving centre transceiver (RCT) installed in ARC and used in alarm transmission systems. The alarm transmission system requirements and classifications are defined within EN 50136 1. Different types of alarm systems may in addition to alarm messages also send other types of messages, e.g. fault messages and status messages. These messages are also considered to be alarm messages. The term alarm message is used in this broad sense throughout the document. Where application specific standards exist, the RCT should comply with relevant standards called up by that application. The RCT can be either an integrated element of any receiving/annunciation equipment, or a stand-alone device. In either case, the requirements of this European Standard should apply. The function of the RCT is to monitor the ATPs, receive alarm messages, forward alarm messages to one or more AEs and send acknowledgements to the SPTs. Management of the transmission network is not in the scope of this European Standard.
- Amendment10 pagesEnglish languagesale 10% offe-Library read for×1 day
This document applies to interconnections between intrusion and hold-up alarm system components using specific or non-specific wired interconnections (e.g. between SPT and CIE). The interconnected components are located within the supervised premises, or mounted on the outside of the supervised premises (e.g. external warning devices). This document does not apply to interconnections between components located within the same enclosure, or to interconnections between parts of an I&HAS component if covered by the relevant product standard. This document does not define the physical requirements of the interconnection media. This document is expected to be used in conjunction with the other parts of the EN 50131 series that define the functional requirements of the equipment regardless of the interconnection technique used. Where monitoring of the functionality of the interconnections is undertaken by an interconnected component, this is defined in the relevant product standard in the EN 50131 series. If a component standard indicates that an interconnection will be monitored, then this document determines the monitored conditions applicable to the interconnection. NOTE 1 For example, if there is no requirement in a detector standard to monitor a remote indication of detection input, this document does not apply to that particular interconnection. Requirements for the monitoring of the functionality of power connections between I&HAS components are defined in the relevant product standard and are not included within this document. This document defines the terms used in the field of intrusion and hold-up alarm equipment using such interconnections and includes the requirements relevant to the equipment interfaces. Wired interconnection media can include metallic single stranded insulated cable, metallic multi-stranded insulated cable, and fibre optic cable. These cables can comprise single or multiple cores. NOTE 2 Interconnections using RF techniques (i.e. wire free interconnections) are dealt with by EN 50131 5 3.
- Technical specification26 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion