This document provides specific rules for the assessment of the release on dangerous substances from glass products into indoor air of buildings in complement to the horizontal rules given in EN 16516.
This document addresses specifically products as mentioned in TC 129 Mandate - M135 Amendment 1 EN (2012), i.e. products covered by the following European Standards: EN 1036 2 and FprEN 16477 2. However, this document can also be applied to other glass products containing volatiles organic compounds (VOC) such as: EN 1279 5, EN 15755 1 and EN 14449. Glass products that do not contain organic compounds are not in the scope of this document (see Annex A).
This document address the release of dangerous substances into indoor air from construction products, although it can also be applied to glass products used in other applications such as furniture.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the testing methodology to be used for glass products that are claiming fire resistance. The methodology covers Type Testing as defined in the relevant glass product standard.
NOTE   This document provides guidance with the declaration of the characteristic, Safety in case of fire − Resistance to fire (for glass for use in a glazed assembly intended specifically for fire resistance) for the CE marking.
The same methodology can also be used to determine the performance classification for market applications (see Annex B).
The methodology covers all glass product types that may require testing and classification for fire resistance.
Fire resistance testing covers end use applications for example:
-   doors;
-   partitions, walls (including curtain walling);
-   floors, roofs;
-   ceilings.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a test method for determining the mechanical viscoelastic properties of interlayer materials. The interlayers under examination are those used in the production of laminated glass and/or laminated safety glass.  The interlayer properties are needed in order to determine the load resistance of laminated glass in accordance with prEN 16612 [1].
From the tensile modulus in particular conditions of temperature and load duration, an interlayer can be placed into a family that relates to a specific interlayer shear transfer coefficient, .  This value can be used in the simplified calculation method described in prEN 16612 [1].
An informative annex explains the background to the determination of families relating to a specific interlayer shear transfer coefficient.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives a method of determining the design value of the bending strength of glass. It gives:
- the general method of calculation, and
- guidance for lateral load resistance of linearly supported glazed elements used as infill panels;
NOTE   Examples of lateral loads are wind loads and snow loads and self weight of sloping glass and climatic loads on insulating glass units.
This standard gives recommended values for the following factors for glass as a material:
-  material partial factors, γM;A and γM;v ;
-  factors for the load duration, kmod ;
- partial factor for actions, γG , γQ , and ψ ;
- factor for stressed edges, ke.
Most glass in buildings is used as infill panels.  Infill panels are in a class of consequence lower than those covered in EN 1990, so proposed values for the partial load factors, γQ and γG, are given for infill panels.
The action of climatic loads on insulating glass units is not covered by Eurocodes, so this document also gives proposed values of partial factors, ψ0, ψ1 and ψ2, for this action.
This European Standard does not determine suitability for purpose. Resistance to lateral loads is only one part of the design process, which may also need to take into account, for example:
- in-plane loading, buckling, lateral torsional buckling, and shear forces
- environmental factors (e.g. sound insulation, thermal properties),
- safety characteristics which cannot be calculated (e.g. fire performance, breakage characteristics in relation to human safety, security, containment).
This European Standard does not apply to channel shaped glass.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers all life cycle stages, from cradle to grave, namely product stage, construction process stage, use stage and end-of-life stage of glass products (see point 4), used in buildings.
While covering all life cycle stages, this PCR primarily focuses on the product stage, in particular the manufacturing of flat glass and the consequent processing into flat glass products (as listed in point 4.), from cradle to gate. It covers raw materials and energy supply, transport, flat glass manufacturing, flat glass processing, packaging and storage.  
All requirements and recommendations in this PCR for the elaboration of the Life Cycle Inventory may be applicable to flat glass used in other applications, such as flat glass used in automotive.
This PCR includes the rules to produce EPD that contains more than one thickness or configuration of the same product.
This European Standard does not apply to glass blocks, glass paver units (EN 1051-1) and channel-shaped glass (EN 572-7, EN 15683-1).

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers all life cycle stages, from cradle to grave, namely product stage, construction process stage, use stage and end-of-life stage of glass products (see Clause 4), used in buildings.
While covering all life cycle stages, this PCR primarily focuses on the product stage, in particular the manufacturing of flat glass and the consequent processing into flat glass products (as listed in point 4.), from cradle to gate. It covers raw materials and energy supply, transport, flat glass manufacturing, flat glass processing, packaging and storage.
All requirements and recommendations in this PCR for the elaboration of the Life Cycle Inventory may be applicable to flat glass used in other applications.
This PCR includes the rules to produce EPD that contains more than one thickness or configuration of the same product.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives a method of determining the design value of the bending strength of glass. It gives:the general method of calculation, and guidance for lateral load resistance of linearly supported glazed elements used as infill panels
NOTE   Examples of lateral loads are wind loads, snow loads, self weight of sloping glass, and cavity pressure variations on insulating glass units.
This document gives recommended values for the following factors for glass as a material:
- material partial factors, M;A and M;v ;
- factors for the load duration, kmod ;
- factor for stressed edges, ke.
Most glass in buildings is used as infill panels.  This document covers those infill panels that are in a class of consequence lower than those covered in EN 1990, so proposed values for the partial load factors, yQ and yG, are given for these infill panels.
The action of cavity pressure variations on insulating glass units is not covered by Eurocodes, so this document also gives proposed values of partial factors, 0, 1 and 2, for this action.
This document does not determine suitability for purpose. Resistance to lateral loads is only one part of the design process, which could also need to take into account:
-   in-plane loading, buckling, lateral torsional buckling, and shear forces,
-   environmental factors (e.g. sound insulation, thermal properties),
-   safety characteristics (e.g. fire performance, mode of breakage in relation to human safety, security).
This document does not apply to channel shaped glass, glass blocks and pavers, or vacuum insulated glass units.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for determining the mechanical viscoelastic properties of interlayer materials. The interlayers under examination are those used in the production of laminated glass and/or laminated safety glass. The interlayer viscoelastic properties are needed in order to determine the load resistance of laminated glass.
From the tensile modulus in particular conditions of temperature and load duration, an interlayer can be placed into a family that relates to a specific interlayer shear transfer coefficient.  This value can be used in the simplified calculation method described in EN 16612.
Informative Annex D explains the background to the determination of families relating to a specific interlayer shear transfer coefficient.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance which enables assessment of compliance with the acoustic requirements of buildings.
Rigorous technical analysis of measurement data remains an option, but this standard is intended to enable the derivation of simpler indices of performance, which can be adopted with confidence by non-specialists.
By adopting the principles of this standard the formulation of acoustic requirements in Building Codes and for product specification to satisfy particular needs for glazing is simplified.
It is recognised that the acoustic test procedures contained within EN ISO 140-1 and EN ISO 140-3 relate only to glass panes and their combinations. Although the same principles should be followed as closely as possible, it is inevitable that some compromises are necessary, because of the bulkier construction of other glazing types, e.g. glass blocks, paver units, channel-shaped glass, structural glazing and structural sealant glazing. Guidelines on how to adapt the test procedures for these glazing types are offered in Clause 4.
All the considerations of this standard relate to panes of glass/glazing alone. Incorporation of them into windows may cause changes in acoustic performance as a result of other influences, e.g. frame design, frame material, glazing material/method, mounting method, air tightness, etc. Measurements of the sound insulation of complete windows (glass and frame) may be undertaken to resolve such issues.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance which enables assessment of compliance with the acoustic requirements of buildings.
Rigorous technical analysis of measurement data remains an option, but this standard is intended to enable the derivation of simpler indices of performance, which can be adopted with confidence by non-specialists.
By adopting the principles of this standard the formulation of acoustic requirements in Building Codes and for product specification to satisfy particular needs for glazing is simplified.
It is recognised that the acoustic test procedures contained within EN ISO 140-1 and EN ISO 140-3 relate only to glass panes and their combinations. Although the same principles should be followed as closely as possible, it is inevitable that some compromises are necessary, because of the bulkier construction of other glazing types, e.g. glass blocks, paver units, channel-shaped glass, structural glazing and structural sealant glazing. Guidelines on how to adapt the test procedures for these glazing types are offered in Clause 4.
All the considerations of this standard relate to panes of glass/glazing alone. Incorporation of them into windows may cause changes in acoustic performance as a result of other influences, e.g. frame design, frame material, glazing material/method, mounting method, air tightness, etc. Measurements of the sound insulation of complete windows (glass and frame) may be undertaken to resolve such issues.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard specifies a procedure for determining the emissivity at room temperature of the surfaces of glass, coated glass and other glazing components not transparent in the far infrared. The emissivity is necessary for taking into account heat transfer by radiation from surfaces at the standard temperature of 283 K in the determination of the U value and of the total solar transmittance of glazing according to B.1 to B.5.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a procedure for determining the emissivity at room temperature of the surfaces of glass and coated glass.
The emissivity is necessary for taking into account heat transfer by radiation from surfaces at the standard temperature of 283 K in the determination of the U value and of the total solar transmittance of glazing according to [1] to [4].
The procedure, being based on spectrophotometric regular reflectance measurements at near normal incidence on materials that are non-transparent in the infrared region, is not applicable to glazing components with at least one of the following characteristics:
a) with rough or structured surfaces where the incident radiation is diffusely reflected;
b) with curved surfaces where the incident radiation is regularly reflected at angles unsuitable to reach the detector while using regular reflectance accessories;
c) infrared transparent.
However, it can be applied with caution to any glazing component provided its surfaces are flat and non-diffusing (see 3.6) and it is non-transparent in the infrared region (see 3.7).
Although transmittance measurements are included in this document, they are only necessary to check if the sample is non-transparent in the infrared region in the context of this document (see 3.7). If the sample is transparent in the infrared region, this document is not applicable.
The previous version of this document was based on the use of reflectance measurements using double beam dispersive infrared spectrophotometers capable of measuring over almost the entire spectral range of a black body at the standard reference temperature and determining the emissivity by the 30 ordinate method [6]. This version takes account of Fourier Transform Infrared (FTIR) spectrophotometers where the spectral range is limited. It describes a method whereby spectrophotometers can be used to determine emissivity if they are able to measure up to the 24th ordinate point and if they satisfy a noise criterion for this spectral range. It allows the inclusion of data from the 25th ordinate point up to the 30th ordinate point. A new informative annex (Annex D) describing the principles of absolute reflection accessories has been added to this version. These accessories are intended to be used by qualified personnel.
As FTIR spectrophotometers are single beam instruments as opposed to dispersive spectrophotometers which are double beam instruments (and thus able to correct for instrument drift), a procedure was developed by the European funded project, THERMES, to correct for drift. This procedure is described in [10] and [16]. Other categories of ordinate errors using FTIR spectrophotometers are discussed in [14].

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes the test method for the determination of gas leakage rate and specifies the requirements for limit values for gas leakage rate and gas concentration for gas filled insulating glass units made
a) in accordance with prEN 1279-1:2015 and prEN 1279-6:2015 or
b) for the purpose to demonstrate that components (e.g. edge seals or spacers) will allow the insulating glass unit to conform to the requirements given in prEN 1279-1:2015, Clause 6.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard (all parts) covers the requirements for insulating glass units. The main intended uses of the insulating glass units are installations in windows, doors, curtain walling, structural sealant glazing, roofs and partitions.
The achievement of the requirements of this standard indicates that insulating glass units fulfil the needs for intended use and ensures by means of the evaluation of conformity to this standard that, visual, energetic, acoustic, safety parameters do not change significantly over time.
In cases where there is no protection against direct ultra-violet radiation or permanent shear load at the edges, as in structural sealant glazing systems, it is essential to follow additional European technical specifications (see EN 15434 and EN 13022-1).
Insulating glass units that are intended for artistic purposes (e.g. lead glass or fused glass) are excluded from the scope of this standard.
Glass/plastics composites are under the scope as long as the surface of contact with sealants is a glass component.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
This European Standard gives definitions for insulating glass units and covers the rules for the system description, the optical and visual quality and the dimensional tolerances thereof and describes the substitution rules within an existing system description. It also provides informative guidance for the installation of insulating glass units in windows or facades.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements and describes the test methods for edge seal components and inserts. This includes the identification, the determination of physical attributes and the evaluation of characteristics for use in substitution rules in accordance with prEN 1279-1:2015.
For the purpose to demonstrate that edge seal components will allow the insulating glass unit to conform to the requirements given in prEN 1279-1:2015, Clause 6, prEN 1279-2:2015 and prEN 1279-3:2015 also apply.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes the routine factory production control, the periodic testing and inspection and test methods to verify that an insulating glass unit (IGU) conforms to the system description.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the evaluation of conformity and the factory production control of insulating glass units (IGU) for use in buildings.
NOTE 1    For glass products with electrical wiring or connections for e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
NOTE 2   Units for which the intended use is only ‘artistic’ and therefore no essential requirement is required, are not subject to CE marking and are not part of this standard.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes the test method for the determination of moisture penetration index and specifies the requirements for limit values for insulating glass units made
a) in accordance with prEN 1279-1:2015 and prEN 1279-6:2015 or
b) for the purpose to demonstrate that components (e.g. edge seals or spacers) will allow the insulating glass unit to conform to the requirements given in prEN 1279-1:2015, Clause 6.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes the test method for the determination of gas leakage rate and specifies the requirements for limit values for gas leakage rate and gas concentration for gas filled insulating glass units made
a)   in accordance with EN 1279 1:2018 and manufactured to EN 1279 6:2018, or
b)   for the purpose to demonstrate that components (e.g. edge seals or spacers) will allow the insulating glass unit to conform to the requirements given in EN 1279 1:2018, Clause 6.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes the routine factory production control, the periodic testing and inspection and test methods to verify that an insulating glass unit (IGU) conforms to the system description.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes the test method for the determination of moisture penetration index and specifies the requirements for limit values for insulating glass units made
a)   in accordance with EN 1279 1:2018 and manufactured to EN 1279 6:2018; or
b)   for the purpose to demonstrate that components (e.g. edge seals or spacers) will allow the insulating glass unit to conform to the requirements given in EN 1279 1:2018, Clause 6.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the product standard of insulating glass units (IGU) for use in buildings.
Units for which the intended use is only artistic and therefore no essential characteristics are required, are not subject to CE marking and are not part of this standard.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document (all parts) covers the requirements for insulating glass units. The main intended uses of the insulating glass units are installations in windows, doors, curtain walling, bonded glazing for doors, windows and curtain walling, roofs and partitions.
The achievement of the requirements of this standard indicates that insulating glass units fulfil the needs for intended use and ensures by means of the evaluation of conformity to this standard that, visual, energetic, acoustic, safety parameters do not change significantly over time.
In cases where there is no protection against direct ultraviolet radiation or permanent shear load on the edge seal, as in bonded glazing for doors, windows and curtain walling systems, it is essential to follow additional European Technical Specifications (see EN 15434, EN 13022 1 and prEN 16759).
Insulating glass units that are intended for artistic purposes (e.g. lead glass or fused glass) are excluded from the scope of this standard.
Vacuum insulating glass is not covered by this standard (see ISO DIS 19916 1).
Glass/plastics composites are under the scope as long as the surface of contact with sealants is a glass component.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
This European Standard gives definitions for insulating glass units and covers the rules for the system description, the optical and visual quality and the dimensional tolerances thereof and describes the substitution rules based on an existing system description.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and describes the test methods for edge seal components and inserts. This includes the identification, the determination of physical attributes and the evaluation of characteristics for use in substitution rules in accordance with EN 1279 1:2018.
For the purpose to demonstrate that edge seal components will allow the insulating glass unit to conform to the requirements given in EN 1279 1:2018, Clause 6, EN 1279 2:2018 and EN 1279 3:2018 also apply.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the evaluation of conformity and the factory production control of basic alumino silicate glass products for use in buildings.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers electrically operated metal fans for chimneys that are able to create a stable positive or negative pressure for the chimney.
This European Standard covers fans installed inline in the connecting flue pipe (inline fans) or mounted on the chimney outlet (exhaust fans).
This standard excludes chimney cowls (Terminals with aerodynamic characteristics).

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the assessment and verification of constancy of performance and the factory production control of basic alumino silicate glass products for use in buildings.
NOTE   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic glass products and indicates their chemical composition, their main physical and mechanical characteristics and defines their general quality criteria.
Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this Part, but are given in other Parts of EN 572 specific to each product type:
-   EN 572-2   Float glass;
-   EN 572-3   Polished wired glass;
-   EN 572-4   Drawn sheet glass;
-   EN 572-5   Patterned glass;
-   EN 572-6   Wired patterned glass;
-   EN 572-7   Wired or unwired channel shaped glass;
-   EN 572-8   Supplied and final cut sizes;
-   EN 572-9   Evaluation of conformity/Product standard.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for basic soda lime silicate glass products, as defined in EN 572-1:2012, for use in building. It applies to supplied sizes or cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².
This European Standard does not apply to float glass supplied as jumbo, split sizes or oversize plates nor to polished wired glass, drawn sheet glass, patterned glass, patterned wired glass supplied as stock sizes. For specifications regarding these types of glass, see EN 572-2:2012, EN 572-3:2012, EN 572-4:2012, EN 572-5:2012 and EN 572-6:2012 respectively.
This European Standard does not apply to final cut sizes of wired or unwired channel shaped glass For specifications on this type of glass, see EN 572-7:2012.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for basic soda lime silicate glass products, as defined in EN 572-1:2012, for use in building. It applies to supplied sizes or cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m².
This European Standard does not apply to float glass supplied as jumbo, split sizes or oversize plates nor to polished wired glass, drawn sheet glass, patterned glass, patterned wired glass supplied as stock sizes. For specifications regarding these types of glass, see EN 572-2:2012, EN 572-3:2012, EN 572-4:2012, EN 572-5:2012 and EN 572-6:2012 respectively.
This European Standard does not apply to final cut sizes of wired or unwired channel shaped glass For specifications on this type of glass, see EN 572-7:2012.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic glass products and indicates their chemical composition, their main physical and mechanical characteristics and defines their general quality criteria.
Specific dimensions and dimensional tolerances, description of faults, quality limits and designation for each basic product type are not included in this Part, but are given in other Parts of EN 572 specific to each product type:
-   EN 572-2   Float glass;
-   EN 572-3   Polished wired glass;
-   EN 572-4   Drawn sheet glass;
-   EN 572-5   Patterned glass;
-   EN 572-6   Wired patterned glass;
-   EN 572-7   Wired or unwired channel shaped glass;
-   EN 572-8   Supplied and final cut sizes;
-   EN 572-9   Evaluation of conformity/Product standard.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of this European Standard specifies and classifies basic alumino silicate glass products, indicates their chemical composition, their main physical and mechanical characteristics, their dimensional and their minimum quality requirements (in respect of optical and visual faults).
This European Standard applies to basic alumino silicate glasses supplied in stock sizes, supplied sizes or in cut sizes for final end use.
This European Standard does not apply to final cut sizes having a dimension less than 100 mm or a surface area less than 0,05 m2.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13022-2 deals with the assembling and bonding of glass elements in a frame, window, door or curtain walling construction, or directly into the building by means of structural bonding of the glass element into or onto framework or directly into the building. It gives information to the assembler to enable him to organise his work and comply with requirements regarding quality control. Structural sealant glazing can be incorporated into the façades (curtain walls, doors and windows) or roofs as follows: - either vertically; or - up to 7° from the horizontal, i.e. 83o from the vertical. This European Standard only deals with the bonding to glass surfaces, i.e. coated or uncoated or enamelled, and metallic surfaces, i.e. aluminium (anodised or coated), stainless steel, as considered in G.2 of EN 15434:2006+A1:2010.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13022-1 specifies requirements for the suitability for use of supported and unsupported glass products for use in “Structural Sealant Glazing” (SSG) applications. Four schematic drawings of SSG systems are shown in Figure 1 and three section drawings of an SSG type II system are shown in Figure 2 for illustration purposes. This European Standard on glass products is considered as a supplement to the requirements specified in the corresponding standards with regard to verifying the suitability for use in SSG systems. Only soda lime silicate glasses are taken into consideration in this European Standard. Plastic glazing is excluded from the scope of this European Standard. Any glass products meeting the requirements of this European Standard are suitable for use in SSG systems as defined in ETAG 002) “Structural sealant glazing system”. All glass products are installed and bonded into the support under controlled environmental conditions as described in Clause 5 of FprEN 13022-2:2013. When the outer seal of the insulating glass unit has a structural function and/or is exposed to UV radiation without any protection, only silicone based sealant are permitted in the construction of the unit.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the assembling and bonding of glass elements in a frame, window, door or curtain walling construction, or directly into the building by means of structural bonding of the glass element into or onto framework or directly into the building.
It gives information to the assembler to enable him to organize his work and comply with requirements regarding quality control.
Structural sealant glazing can be incorporated into the façades (curtain walls, doors and windows) or roofs as follows:
-   either vertically; or
-   up to 7° from the horizontal, i.e. 83° from the vertical.
This European Standard only deals with the bonding to glass surfaces, i.e. coated or uncoated or enamelled, and metallic surfaces, i.e. aluminium (anodised or coated), stainless steel, as considered in G.2 of EN 15434:2006+A1:2010.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for the suitability for use of supported and unsupported glass products for use in Structural Sealant Glazing (SSG) applications. Four schematic drawings of SSG systems are shown in Figure 1 and three section drawings of an SSG type II system are shown in Figure 2 for illustration purposes. This European Standard on glass products is considered as a supplement to the requirements specified in the corresponding standards with regard to verifying the suitability for use in SSG systems.
Only soda lime silicate glasses are taken into consideration in this European Standard.
Plastic glazing is excluded from the scope of this European Standard.
Any glass products meeting the requirements of this European Standard are suitable for use in SSG systems as defined in ETAG 002 ) Structural sealant glazing system.
All glass products are installed and bonded into the support under controlled environmental conditions as described in Clause 5 of FprEN 13022-2:20131.
When the outer seal of the insulating glass unit has a structural function and/or is exposed to UV radiation without any protection, only silicone based sealant are permitted in the construction of the unit.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 15683-2 covers the evaluation of conformity and the factory production control of thermally toughened soda lime silicate channel shaped safety glass for use in buildings. This also includes requirements subject to regulation.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the evaluation of conformity and the factory production control of thermally toughened soda lime silicate channel shaped safety glass for use in buildings.
This also includes requirements subject to regulation.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the heat soak process system together with tolerances flatness, edgework, fragmentation and physical and mechanical characteristics of monolithic flat heat soaked thermally toughened alkaline earth silicate safety glass for use in buildings. Information on curved heat soak thermally toughened alkaline earth silicate safety glass is given in Annex B, but this product does not form part of this document. Other requirements, not specified in this document, can apply to heat soaked thermally toughened alkaline earth silicate safety glass which is incorporated into assemblies, e.g. laminated glass or insulating units, or undergo an additional treatment, e.g. coating. The additional requirements are specified in the appropriate product standard EN 15682-2. In this case, heat soaked thermally toughened alkaline earth silicate glass does not lose its mechanical or thermal characteristics.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies tolerances, flatness of web and flanges, flange deviation, edgework, fragmentation and physical and mechanical characteristics of monolithic thermally toughened soda lime silicate channel shaped safety glass for use in buildings. Other requirements, not specified in this document, can apply to thermally toughened soda lime silicate channel shaped safety glass, which undergoes an additional treatment, e.g. coating. The additional requirements are specified in the appropriate product standard EN 15683-2. Thermally toughened soda lime silicate channel shaped safety glass, in this case, does not lose its mechanical or thermal characteristics.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, the evaluation of conformity and the factory production control of flat heat soaked thermally toughened alkaline earth silicate safety glass for use in buildings. For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the heat soak process system together with tolerances flatness, edgework, fragmentation and physical and mechanical characteristics of monolithic flat heat soaked thermally toughened alkaline earth silicate safety glass for use in buildings. Information on curved heat soak thermally toughened alkaline earth silicate safety glass is given in Annex B, but this product does not form part of this document.
Other requirements, not specified in this document, can apply to heat soaked thermally toughened alkaline earth silicate safety glass which is incorporated into assemblies, e.g. laminated glass or insulating units, or undergo an additional treatment, e.g. coating. The additional requirements are specified in the appropriate product standard EN 15682-2. In this case, heat soaked thermally toughened alkaline earth silicate glass does not lose its mechanical or thermal characteristics.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, the evaluation of conformity and the factory production control of flat heat soaked thermally toughened alkaline earth silicate safety glass for use in buildings.
For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies tolerances, flatness of web and flanges, flange deviation, edgework, fragmentation and physical and mechanical characteristics of monolithic thermally toughened soda lime silicate channel shaped safety glass for use in buildings.
Other requirements, not specified in this document, can apply to thermally toughened soda lime silicate channel shaped safety glass, which undergoes an additional treatment, e.g. coating. The additional requirements are specified in the appropriate product standard EN 15683-2. Thermally toughened soda lime silicate channel shaped safety glass, in this case, does not lose its mechanical or thermal characteristics.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in FprEN 572-1:2011, for use in building. This European Standard applies only to wired patterned glass supplied in rectangular panes and in stock sizes. EN 572-8 gives information on patterned wired glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of visual and pattern faults) for patterned glass as defined in FprEN 572-1:2011, for use in building. This European Standard applies only to patterned glass supplied in rectangular panes and in stock sizes. EN 572-8 gives information on patterned glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical, visual and wire faults) for polished wired glass, as defined in FprEN 572-1:2011, for use in building. This European Standard applies only to polished wired glass supplied in rectangular panes and in stock sizes. EN 572-8 gives information on polished wired glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of visual and wire faults) for channel shaped glass, as defined in FprEN 572-1:2011, for use in building. This European Standard covers channel shaped glass supplied in stock sizes and final cut sizes.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for drawn sheet glass, as defined in FpEN 572-1:2011, for use in building. This European Standard applies only to drawn sheet glass supplied in rectangular panes and in stock sizes. EN 572-8 gives information on drawn sheet glass in sizes other than those covered by this European Standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in FprEN 572-1:2011, for use in building. This European Standard applies only to float glass supplied in jumbo sizes split sizes and oversize plates.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day